AL-E720 SINGLE PHASE PERCENTAGE BIASED DIFFERENTIAL PROTECTION RELAY TRAINER
Project Information
- Category: ELECTRICAL ENGINEERING
- Sub Category: POWER SYSTEM AND PROTECTION LAB
- Model Number: AL-E720
Description
AL-E720 SINGLE PHASE PERCENTAGE BIASED DIFFERENTIAL PROTECTION RELAY TRAINER
DIFFERENTIAL RELAY TESTING SYSTEM
Model No.: AL-E720
Quantity: 1 Set
Offered Brand: AMBEYLABS
Product Category: Electrical Protection and Relay Testing
Equipment
-----------------------------------------------------------------------------------------------------------------------------------------
1.
General Description
The
Differential Relay Testing System is an advanced educational laboratory
equipment designed for studying the operating principles, characteristics, and
performance of differential protection relays used in electrical power systems.
The
system is designed to provide practical training in differential protection,
current comparison, relay operating characteristics, current setting, operating
time measurement, and fixed-bias differential protection.
The
complete system shall comprise a single-phase input power supply, single-phase
step-down transformer, variable AC autotransformer (Variac), differential
protection relay, digital measurement instruments, test terminals, electrical
circuit diagram, and necessary connecting leads and safety accessories.
The
complete assembly shall be mounted on a robust industrial-grade
aluminium-profile workstation with an industrial grey front panel.
2.
Detailed Technical Specifications
A. Input Power Supply Module
1.Input supply voltage: 230 V AC ±10%.
2.Frequency: 50 Hz.
3.Phase: Single Phase.
4.Main power ON/OFF switch.
5.MCB-based input protection.
6.Power indication lamp.
7.Proper input supply terminals.
8.Suitable overload and short-circuit
protection.
9.Proper electrical earthing arrangement.
B. Single-Phase Transformer Module
1.Type: Single-phase step-down transformer.
2.Primary input voltage: 230 V AC.
3.Secondary output voltage: 24 V AC.
4.Rated output current: 3 A.
5.Transformer capacity: 72 VA.
6.Suitable for supplying the experimental
circuits.
7.Properly insulated primary and secondary
windings.
8.Separate primary and secondary connection
terminals.
9.Clearly identified input and output
terminals.
C. Single-Phase Variac Module
1.Type: Single-phase variable
autotransformer.
2.Input voltage: 230 V AC.
3.Variable output voltage: 0–270 V AC.
4.Output current: 0–2 A.
5.Continuously adjustable output voltage.
6.Rotary voltage adjustment knob.
7.Digital AC voltage indication.
8.Digital AC current indication.
9.Separate output connection terminals.
10. Suitable electrical
protection arrangement.
D. Differential Protection Relay Module
1.Type: Differential Protection Relay.
2.Normal operating voltage: 110 V AC, 50
Hz.
3.Current setting range: 0.2 A to 0.8 A.
4.Operating time: 25 milliseconds.
5.Biasing arrangement: Fixed Type.
6.Adjustable current setting facility.
7.Relay operating and tripping arrangement.
8.Suitable relay contact output terminals.
9.Provision for demonstrating differential
current protection.
10. Suitable for studying
electrical fault detection and protection principles.
E. Digital Measurement Module
The
system shall include digital measurement facilities for monitoring electrical
parameters.
1.Digital AC voltage meter.
2.Digital AC current meter.
3.Seven-segment LED display.
4.Clearly identified measurement sections.
5.Suitable measuring terminals.
6.Provision for monitoring voltage and
current during experiments.
7.Properly insulated measurement connections.
F. Differential Relay Test Terminal Module
1.Separate primary current input terminals
(I₁).
2.Separate secondary current input
terminals (I₂).
3.Differential current measurement
terminals.
4.Red and black safety connection sockets.
5.Clearly identified terminal markings.
6.Suitable for experimental current
comparison.
7.Provision for connecting the relay
testing circuit.
G. Circuit Diagram and Experimental Connection Panel
1.Printed electrical circuit diagram.
2.Input AC supply representation.
3.Variac connection representation.
4.Single-phase transformer connection
representation.
5.Differential relay connection
representation.
6.Primary and secondary current paths.
7.Differential current identification.
8.Clearly labelled electrical connection
points.
3.
Mechanical Construction
Industrial Aluminium Profile Workstation
1.Heavy-duty industrial-grade aluminium
profile structure.
2.Silver-grey aluminium frame.
3.Industrial grey front panel.
4.Blue reinforced corner connectors.
5.Side-mounted carrying handles.
6.Stable base with adjustable supporting
feet.
7.Proper mounting arrangement for all
electrical components.
8.Durable and corrosion-resistant finish.
9.Clearly identified control and
measurement sections.
10. Compact tabletop laboratory
design.
4.
Experiments and Training Capabilities
The
system shall facilitate the following practical experiments:
1.Study of differential protection relay
construction and working principles.
2.Study of differential protection in
electrical power systems.
3.Study of current comparison principles.
4.Measurement and analysis of differential
current.
5.Study of differential relay current
setting.
6.Verification of relay operating current.
7.Study of fixed-bias differential
protection.
8.Measurement of differential relay
operating time.
9.Study of relay tripping characteristics.
10. Demonstration of transformer
differential protection principles.
11. Study of relay response under
normal operating conditions.
12. Study of relay operation
under differential fault conditions.
13. Study of electrical fault
detection techniques.
14. Study of protective relay
applications in power systems.
15. Practical demonstration of
electrical protection schemes.
5.
Standard Scope of Supply
|
Sr. No. |
Description |
Quantity |
|
1 |
Complete Differential Relay Testing System |
1 Set |
|
2 |
Single-phase transformer (230 V / 24 V, 3 A) |
1 No. |
|
3 |
Single-phase Variac (230 V / 0–270 V, 0–2 A) |
1 No. |
|
4 |
Differential protection relay |
1 No. |
|
5 |
Digital AC voltage meter |
1 No. |
|
6 |
Digital AC current meter |
1 No. |
|
7 |
Input power supply module with MCB |
1 Set |
|
8 |
Differential relay test terminal module |
1 Set |
|
9 |
Electrical circuit diagram panel |
1 No. |
|
10 |
Electrical connecting leads |
1 Set |
|
11 |
Safety accessories and interconnections |
1 Set |
|
12 |
Operating and experiment manual |
1 Set |
6.
Safety Features
1.Main power ON/OFF switch.
2.MCB-based input protection.
3.Overload and short-circuit protection.
4.Proper electrical earthing.
5.Insulated electrical connection
terminals.
6.Protection for variable AC output.
7.Clearly marked input and output
terminals.
8.Electrical warning labels.
9.Proper cable routing and management.
10. Safe arrangement for
laboratory experiments.
7.
General Requirements
· Complete equipment shall be
supplied in ready-to-operate condition.
· All electrical components
shall be properly mounted and interconnected.
· All terminals shall be
clearly identified.
· All necessary connecting
leads and accessories shall be supplied.
· Detailed operating
instructions and experiment manuals shall be provided.
· Installation, commissioning,
and demonstration shall be included.
· Warranty and after-sales
technical support shall be provided.
8.
Offered Product Details
|
Particulars |
Offered Specification |
|
Brand |
AMBEYLABS |
|
Model Number |
AL-E720 |
|
Product Name |
Differential Relay Testing System |
|
Quantity |
1 Set |
|
Input Supply |
230 V AC ±10% |
|
Frequency |
50 Hz |
|
Phase |
Single Phase |
|
Transformer |
230 V / 24 V AC, 3 A |
|
Transformer Capacity |
72 VA |
|
Variac Input |
230 V AC |
|
Variac Output |
0–270 V AC |
|
Variac Current |
0–2 A |
|
Relay Type |
Differential Protection Relay |
|
Relay Normal Voltage |
110 V AC, 50 Hz |
|
Current Setting |
0.2–0.8 A |
|
Operating Time |
25 ms |
|
Biasing |
Fixed Type |
|
Dimensions |
830 × 350 × 645 mm (W × D × H) |
|
Construction |
Aluminium Profile Workstation |
|
Colour Scheme |
Industrial Grey / Silver with Blue Connectors |
|
Application |
Electrical Protection and Relay Testing Laboratory |
9.
Important Technical Clarifications
Before
final manufacturing and tender submission, verify the following:
· The 24 V AC, 3 A transformer
output and 110 V AC relay operating requirement are different ratings; the
actual relay supply and test circuit must be designed accordingly.
· Confirm whether the Variac
output of 0–270 V AC is isolated or non-isolated. A standard Variac is
generally an autotransformer and does not provide galvanic isolation.
· Confirm the differential
relay's actual current injection arrangement and operating time measurement
method.
· Ensure suitable current
limiting and protection for all test connections.
Note: The above specification is
prepared for Model AL-E720 based on the supplied technical particulars.
Additional unprovided ratings have not been assumed.