AL-E281F ABCD PARAMETERS OF TRANSMISSION LINE (3-PHASE BENCH MODEL)
Project Information
- Category: ELECTRICAL ENGINEERING
- Sub Category: POWER SYSTEM AND PROTECTION LAB
- Model Number: AL-E281F
Description
AL-E281F ABCD PARAMETERS OF TRANSMISSION LINE (3-PHASE
BENCH MODEL)
ABCD PARAMETERS OF TRANSMISSION LINE (3-PHASE BENCH MODEL)
Model No.: AL-E281F
Quantity: 1 Set
Offered Brand: AMBEYLABS
Product Category:
Electrical Power Systems and Transmission Line Training Equipment
-----------------------------------------------------------------------------------------------------------------------------------------1.
General Description
The ABCD Parameters of Transmission Line (3-Phase Bench Model) is an
advanced electrical engineering laboratory training system designed for
studying the performance and characteristics of three-phase transmission lines.
The system shall facilitate practical experiments related to
transmission line modelling, determination of ABCD parameters, voltage
regulation, transmission efficiency, sending-end and receiving-end
measurements, and the effect of different loading conditions.
The complete system shall consist of six π-section transmission line
modules incorporating iron-cored inductors and capacitors, three-phase input
supply, three-phase Dimmerstat, digital measuring instruments, analogue LPF
wattmeters, three-phase resistive load bank, MCB protection, and BTI connection
terminals.
The complete arrangement shall be mounted on a robust industrial-grade
panel with clearly identified components, measurement sections, and circuit
diagrams.
2. Detailed Technical Specifications
A. Main Input Power Supply Module
1.
Input
supply: 415 V AC, three-phase.
2.
System
voltage: 230 V AC (Line to Neutral).
3.
Line-to-line
voltage: 400 V AC.
4.
Rated
current: 5 A.
5.
Three-phase
input connection arrangement.
6.
Main power
ON/OFF switch.
7.
R-Y-B
phase indication lamps.
8.
MCB-based
input protection.
9.
Proper
electrical earthing arrangement.
10. Clearly identified input supply terminals.
B. Three-Phase Dimmerstat Module
1.
Type:
Three-phase variable autotransformer (Dimmerstat).
2.
Quantity:
1 No.
3.
Input
supply: 415 V AC, three-phase.
4.
Rated
current: 8 A.
5.
Continuously
adjustable output voltage.
6.
Rotary
voltage adjustment control.
7.
Suitable
for controlling the experimental transmission line input voltage.
8.
Properly
identified input and output terminals.
9.
Suitable
electrical protection arrangement.
10. Heavy-duty industrial construction.
C. Transmission Line π-Section Module
The system shall consist of six π-section transmission line modules
designed to simulate the electrical characteristics of a three-phase
transmission line.
·
Number of
π-sections: 6 Nos.
·
Total
iron-cored inductors: 18 Nos.
·
Total
capacitors: 18 Nos.
·
Inductors:
Iron-cored type.
·
Configuration:
Six-section π-network arrangement.
·
Suitable
for studying transmission line electrical parameters.
·
Properly
identified input and output connections.
·
Provision
for interconnecting individual π-sections.
·
Suitable
for studying short, medium and equivalent transmission line models through
appropriate section configurations.
D. Iron-Cored Inductors
1.
Quantity:
18 Nos.
2.
Type:
Iron-cored inductors.
3.
Suitable
for representing transmission line series inductance.
4.
Designed
for integration into the six π-section modules.
5.
Proper
mounting and electrical insulation.
6.
Clearly
identified connection terminals.
7.
Suitable
for transmission line parameter experiments.
E. Capacitor Module
1.
Quantity:
18 Nos.
2.
Type:
Capacitors suitable for AC transmission line simulation.
3.
Suitable
for representing transmission line shunt capacitance.
4.
Integrated
into six π-section modules.
5.
Properly
insulated construction.
6.
Clearly
identified connection terminals.
7.
Suitable
for studying charging current and capacitive effects.
F. Digital Measurement Instruments
The system shall include digital instruments for monitoring electrical
voltage and current parameters.
Digital AC Voltmeters
·
Quantity:
2 Nos.
·
Measurement
range: 0–500 V AC.
·
Digital
LED display.
·
Suitable
for measuring AC voltage.
·
Panel-mounted
construction.
·
Clearly
identified measurement connections.
Digital AC Ammeters
·
Quantity:
2 Nos.
·
Measurement
range: 0–20 A AC.
·
Digital
LED display.
·
Suitable
for monitoring transmission line current.
·
Panel-mounted
construction.
·
Suitable
for experimental measurement applications.
G. Analogue LPF Wattmeters
1.
Type: Low
Power Factor (LPF) wattmeters.
2.
Quantity:
4 Nos.
3.
Mounting:
Panel-mounted analogue type.
4.
Voltage
range: 0–500 V.
5.
Current
range: 5 A.
6.
Analogue
pointer-type indication.
7.
Clearly
graduated measurement scale.
8.
Suitable
for measuring power under low power factor conditions.
9.
Suitable
for three-phase transmission line power measurement.
10. Properly identified voltage and current
connections.
H. Three-Phase Resistive Load Bank
1.
Type:
Three-phase resistive load bank.
2.
Rated
current: 5 A per phase.
3.
Three-phase
R-Y-B load arrangement.
4.
Resistive
loading facility.
5.
Individual
phase load connection arrangement.
6.
Suitable
switching arrangement for load variation, as configured.
7.
Clearly
identified load terminals.
8.
Suitable
for studying transmission line performance under different loading conditions.
I. BTI Connection Terminal Module
1.
Quantity:
30 Nos.
2.
Type: BTI
electrical connection terminals.
3.
Suitable
for experimental circuit interconnections.
4.
Colour-coded
terminals for phase identification.
5.
Properly
insulated construction.
6.
Clearly
identified connection points.
7.
Suitable
for connecting transmission line sections, measuring instruments and load bank.
8.
Suitable
for repeated laboratory experiments.
3. Mechanical Construction and Panel Details
Industrial Electrical Training Panel
1.
Panel
type: Closed-type laboratory training panel.
2.
Panel
material: Industrial-grade sheet metal / suitable panel construction.
3.
Panel
dimensions:
o Height: 2 ft.
o Width: 4 ft.
o Depth: 200 mm.
4.
Approximate
metric dimensions: 610 × 1220 × 200 mm (H × W × D).
5.
Heavy-duty
supporting structure.
6.
Industrial
grey and silver finish.
7.
Blue
reinforced corner connectors, where applicable.
8.
Proper mounting
arrangement for all electrical components.
9.
Clearly
printed panel layout and circuit diagrams.
10. Proper cable routing and internal wiring.
11. Suitable for electrical engineering laboratory
applications.
4. Experiments and Training Capabilities
The system shall facilitate the following practical experiments:
1.
Study of
three-phase transmission line characteristics.
2.
Study of
transmission line equivalent circuits.
3.
Study of
six-section π-network transmission line models.
4.
Determination
of ABCD parameters of transmission lines.
5.
Determination
of transmission line resistance and reactance.
6.
Study of
transmission line inductance and capacitance.
7.
Study of
sending-end voltage and current.
8.
Study of
receiving-end voltage and current.
9.
Determination
of voltage regulation.
10. Determination of transmission efficiency.
11. Study of the effect of load variation on
transmission line performance.
12. Study of resistive loading characteristics.
13. Measurement of sending-end power.
14. Measurement of receiving-end power.
15. Study of transmission line power losses.
16. Study of voltage drop under different loading
conditions.
17. Study of power factor effects on transmission line
performance.
18. Study of capacitive charging current.
19. Study of the effect of line capacitance on voltage
regulation.
20. Comparison of transmission line performance under
different operating conditions.
5. Standard Scope of Supply
|
Sr. No. |
Description |
Quantity |
|
1 |
Complete ABCD Parameters of Transmission Line Training System |
1 Set |
|
2 |
Three-phase π-section transmission line modules |
6 Nos. |
|
3 |
Iron-cored inductors |
18 Nos. |
|
4 |
Capacitors |
18 Nos. |
|
5 |
Three-phase Dimmerstat, 8 A |
1 No. |
|
6 |
Digital AC voltmeters (0–500 V) |
2 Nos. |
|
7 |
Digital AC ammeters (0–20 A) |
2 Nos. |
|
8 |
Analogue LPF wattmeters (0–500 V, 5 A) |
4 Nos. |
|
9 |
Three-phase resistive load bank (5 A/phase) |
1 Set |
|
10 |
MCB protection arrangement |
1 Set |
|
11 |
BTI connection terminals |
30 Nos. |
|
12 |
Main input supply and phase indication module |
1 Set |
|
13 |
Electrical connecting leads |
1 Set |
|
14 |
Internal wiring and interconnection accessories |
1 Set |
|
15 |
Circuit diagrams and identification labels |
1 Set |
|
16 |
Operating and experiment manual |
1 No. |
6. Safety
Features
1.
MCB-based
input supply protection.
2.
Main power
ON/OFF switching facility.
3.
R-Y-B
phase indication lamps.
4.
Proper
electrical earthing.
5.
Insulated
electrical connection terminals.
6.
Suitable
protection for the Dimmerstat.
7.
Proper
insulation of inductors and capacitors.
8.
Clearly
identified input and output terminals.
9.
Proper
internal wiring and cable management.
10. Electrical warning labels and operating
instructions.
7. General Requirements
·
Complete
system shall be supplied in ready-to-operate condition.
·
All
electrical components shall be properly mounted and interconnected.
·
All six
π-sections shall be clearly identified.
·
All
measurement instruments shall be calibrated and properly labelled.
·
All
necessary electrical connecting leads and accessories shall be supplied.
·
Detailed
operating instructions and practical experiment manuals shall be provided.
·
Installation,
commissioning and demonstration shall be included.
·
Warranty
and after-sales technical support shall be provided.
8. Offered Product Details
|
Particulars |
Offered Specification |
|
Brand |
AMBEYLABS |
|
Model Number |
AL-E281F |
|
Product Name |
ABCD Parameters of Transmission Line |
|
Model Type |
Three-Phase Bench Model |
|
Quantity |
1 Set |
|
Number of π-Sections |
6 |
|
Iron-Cored Inductors |
18 Nos. |
|
Capacitors |
18 Nos. |
|
System Voltage |
230 V L-N / 400 V L-L |
|
Input Supply |
415 V AC, 3-Phase |
|
Rated Current |
5 A |
|
Dimmerstat |
3-Phase, 8 A |
|
Digital Voltmeters |
2 × 500 V AC |
|
Digital Ammeters |
2 × 20 A AC |
|
Analogue Wattmeters |
4 × LPF, 500 V, 5 A |
|
Load Bank |
3-Phase Resistive, 5 A/Phase |
|
BTI Terminals |
30 Nos. |
|
Protection |
MCB |
|
Panel Dimensions |
2 ft × 4 ft × 200 mm |
|
Application |
Electrical Power Systems Laboratory |
9.
Important Technical Clarifications
For final manufacturing and tender submission, the following details
should be confirmed:
1.
Individual
inductance values of the 18 iron-cored inductors.
2.
Capacitance
values and voltage ratings of the 18 capacitors.
3.
Exact
electrical arrangement of the six π-sections.
4.
Dimmerstat
output voltage range.
5.
Whether
the 5 A system rating is the maximum continuous line current.
6.
Exact
configuration and switching steps of the resistive load bank.
7.
Wattmeter
accuracy class and low-power-factor rating.
8.
Whether
the 30 BTI terminals are 4 mm safety terminals.
9.
Input
supply frequency and phase sequence requirements.
Note: This specification is prepared based on the
supplied technical particulars for Model AL-E281F. Unspecified component values
have not been assumed. All electrical ratings should be verified against the
actual offered configuration before final tender submission.