AL-E1400 ADVANCED VFD VARIABLE FREQUENCY MOTOR DRIVE TRAINING SYSTEM
Project Information
- Category: ROBOTICS AND MECHATRONICS
- Sub Category: PLC TRAINER
- Model Number: AL-E1400
Description
AL-E1400 ADVANCED VFD VARIABLE FREQUENCY MOTOR DRIVE
TRAINING SYSTEM
DETAILED TECHNICAL SPECIFICATIONS
ADVANCED VFD VARIABLE FREQUENCY MOTOR
DRIVE TRAINING SYSTEM
Model No.: AL-E1400
Quantity: 1 Set
Brand: AMBEYLABS
Product Series: Advanced Flex 5 Series VFD Training System
------------------------------------------------------------------------------------------------------------------------------------------
1. General Description
The Advanced VFD Variable Frequency
Motor Drive Training System is a comprehensive educational workstation designed
for practical training in industrial motor control, variable frequency drives,
electrical drives, and industrial automation.
The system shall provide hands-on
training in VFD configuration, programming, motor speed control, acceleration
and deceleration control, analogue reference signal operation, relay-based
control circuits, and three-phase induction motor operation.
The complete system shall consist of an
industrial-grade variable frequency drive, industrial indication panel, ice
cube control relays, START/STOP push buttons, selector switches, rheostat-based
analogue control modules, three-phase Wye-wound induction motor, electrical
connection terminals, and protective electrical components.
2. Detailed Technical Specifications
A. Variable Frequency Drive
(VFD) Module
- Type: Industrial Variable Frequency
Drive.
- Series: Flex 5 Series or equivalent.
- Suitable for controlling the speed of
three-phase AC induction motors.
- Digital display for frequency and
operating parameter indication.
- Keypad-based parameter setting and
programming facility.
- Adjustable output frequency.
- Provision for motor START/STOP
control.
- Adjustable acceleration and
deceleration time.
- Forward and reverse motor operation,
subject to drive configuration.
- Provision for external analogue speed
reference.
- Built-in motor protection and fault
monitoring.
- Suitable for demonstrating industrial
variable-speed motor control.
B. Industrial Panel Indication
Module
- Industrial-grade panel-mounted
indication lamps.
- Red phase indication.
- Yellow phase indication.
- Blue phase indication.
- Green RUN indication.
- Amber FAULT indication.
- Clearly identified indicator labels.
- Suitable electrical connections for monitoring
system operating status.
C. Ice Cube Control Relay
Module
- Industrial plug-in type control
relays.
- Suitable relay sockets and mounting
arrangement.
- Electromechanical switching contacts.
- Clearly identified coil and contact
terminals.
- Suitable for motor control and
interlocking experiments.
- Provision for relay-based control
circuit demonstrations.
D. Industrial START/STOP
Control Module
- Industrial-grade START push button.
- Industrial-grade STOP push button.
- Suitable NO/NC contact arrangement.
- Panel-mounted control switches.
- Clearly identified push-button
functions.
- Suitable for direct and VFD-based
motor control experiments.
E. Selector Switch Module
- Industrial-grade rotary selector
switches.
- Manual/Automatic selection facility.
- Forward/Off/Reverse selection
facility, subject to VFD configuration.
- Multiple operating-position
arrangement.
- Suitable electrical contact
configuration.
- Clearly marked operating positions.
F. Rheostat-Based Analogue
Speed Control Module
The system shall include analogue
reference control facilities for demonstrating external VFD speed control.
- Adjustable 0–10 V DC control signal.
- Adjustable 5–20 mA control signal, as
specified in the offered configuration.
- Separate control adjustment
arrangements.
- Rotary adjustment knobs.
- Clearly identified signal terminals.
- Positive and negative connection
terminals.
- Suitable for studying analogue speed
reference control.
- Compatible with the supplied VFD
analogue input configuration.
G. Three-Phase Wye-Wound
Induction Motor
- Type: Three-phase AC squirrel-cage
induction motor.
- Winding configuration: Wye (Star)
wound.
- Suitable for operation with the
supplied VFD.
- Industrial-grade motor construction.
- Accessible electrical connection
arrangement.
- Suitable mounting base.
- Shaft-end protection arrangement.
- Suitable for studying motor speed and
operating characteristics.
- Provision for practical demonstration
of variable-frequency motor operation.
H. Electrical Input and VFD I/O
Terminal Module
- Dedicated mains
input connection.
- Main power ON/OFF
switch.
- Separate VFD
input/output connection terminals.
- Digital input
terminals.
- Common terminal.
- Analogue input
terminals.
- Analogue output
terminals, where supported by the supplied drive.
- Clearly
identified terminal markings.
- Insulated safety
connection sockets.
- Proper electrical
wiring and protection arrangements.
I. Circuit Diagram and
Connection Panel
- Printed
electrical circuit diagram.
- VFD input and
output connection representation.
- Three-phase
supply connection.
- Motor connection
representation.
- Control signal
identification.
- Suitable for
teaching and troubleshooting exercises.
3. Mechanical Construction and Enclosure
Industrial Aluminium Profile
Workstation
- Heavy-duty
industrial aluminium profile structure.
- Silver-grey
aluminium frame.
- Industrial grey
front mounting panel.
- Blue reinforced
corner connectors.
- Side-mounted
carrying handles.
- Rigid and stable
construction.
- Adjustable
supporting feet.
- Properly secured
electrical components.
- Professional
industrial finish.
- Suitable for
laboratory tabletop installation and transportation.
4. Experiments and Training Capabilities
The system shall facilitate the
following experiments:
- Introduction to
variable frequency drive technology.
- Study of VFD
construction and operating principles.
- Study of VFD
keypad and parameter programming.
- Starting and
stopping of three-phase induction motors using VFD.
- Speed control of
induction motors through frequency variation.
- Study of
acceleration and deceleration control.
- Study of forward
and reverse motor operation.
- Manual and
automatic motor control.
- Study of
industrial START/STOP control circuits.
- Study of ice cube
relay operation.
- Study of
industrial selector switches.
- Study of phase
indication and RUN/FAULT status.
- Study of 0–10 V
analogue speed reference control.
- Study of analogue
current reference control.
- Study of motor
speed response at different frequencies.
- Study of VFD
fault indication and troubleshooting.
- Study of digital
input and output control.
- Study of VFD and
three-phase motor interfacing.
- Study of
industrial motor control circuit diagrams.
- Demonstration of
industrial variable-speed drive applications.
5. Standard Scope of Supply
|
Sr. No. |
Description |
Quantity |
|
1 |
Complete Advanced VFD Training
Workstation |
1 Set |
|
2 |
Flex 5 Series Variable Frequency
Drive or equivalent |
1 No. |
|
3 |
Industrial panel indication module |
1 Set |
|
4 |
Ice cube control relays with sockets |
1 Set |
|
5 |
Industrial START push button |
1 No. |
|
6 |
Industrial STOP push button |
1 No. |
|
7 |
Manual/Automatic selector switch |
1 No. |
|
8 |
Forward/Off/Reverse selector switch |
1 No. |
|
9 |
0–10 V DC rheostat control module |
1 No. |
|
10 |
5–20 mA analogue control module |
1 No. |
|
11 |
Three-phase Wye-wound induction motor |
1 No. |
|
12 |
VFD I/O terminal module |
1 Set |
|
13 |
Electrical circuit diagram panel |
1 No. |
|
14 |
Electrical connecting leads |
1 Set |
|
15 |
Aluminium profile workstation
structure |
1 Set |
|
16 |
Safety accessories and
interconnections |
1 Set |
|
17 |
Operating and experiment manual |
1 Set |
6. Safety Features
- Main power ON/OFF
switch.
- Suitable
electrical isolation arrangement.
- Overload and
short-circuit protection.
- Proper earthing
arrangement.
- Insulated
electrical terminals.
- Clearly marked
input and output connections.
- Emergency power
isolation facility.
- Suitable
protection for motor shaft and rotating parts.
- Electrical
warning labels and safety instructions.
- Proper cable
routing and management.
7. General Requirements
- Complete system
shall be supplied in ready-to-use condition.
- All electrical
components shall be industrial-grade.
- All modules shall
be properly mounted and labelled.
- The system shall
include all required connecting leads and accessories.
- All control
functions shall be clearly identified.
- Detailed
operating and practical experiment manuals shall be provided.
- Installation,
commissioning, and demonstration shall be included.
- Warranty and
after-sales technical support shall be provided.
8. Offered Product Details
|
Particulars |
Offered Specification |
|
Brand |
AMBEYLABS |
|
Model Number |
AL-E1400 |
|
Product Name |
Advanced VFD Variable Frequency Motor
Drive Training System |
|
Series |
Flex 5 Series or Equivalent |
|
Quantity |
1 Set |
|
Drive Type |
Variable Frequency Drive |
|
Motor Type |
Three-Phase AC Induction Motor |
|
Motor Winding |
Wye (Star) |
|
Control System |
Digital and Analogue |
|
Analogue Voltage Reference |
0–10 V DC |
|
Analogue Current Reference |
5–20 mA (as specified) |
|
Control Components |
Relays, Push Buttons, Selector
Switches |
|
Indication |
Industrial Panel Indication |
|
Construction |
Aluminium Profile Workstation |
|
Frame Colour |
Industrial Grey / Silver |
|
Corner Connectors |
Blue |
|
Application |
Electrical Drives and Industrial
Automation Laboratory |
9. Technical Details to Be Confirmed in Final
Manufacturing Configuration
The following values should be
finalized according to the selected VFD and motor:
- VFD input supply
voltage and phase.
- VFD output
voltage and power rating.
- VFD output
frequency range.
- Motor rated
voltage, power, current and RPM.
- Number of control
relays and contact ratings.
- Analogue current
input compatibility (5–20 mA).
- Digital input/output
configuration.
- Workstation
overall dimensions.
Note: The specification retains the supplied 5–20 mA requirement. The
analogue current signal range must be checked against the selected VFD;
standard industrial drives commonly support 4–20 mA. All ratings should be
verified against the actual manufacturer's datasheets before final tender
submission.