AL-358N 3-PHASE TRANSFORMER TRAINING SYSTEM

Project Information

  • Category: ELECTRICAL ENGINEERING
  • Sub Category: ELECTRICAL ENGINEERING
  • Model Number: AL-358N

Description

AL-358N 3-PHASE TRANSFORMER TRAINING SYSTEM

Model: AL-E358N

Educational Transformer Training System

Rating: 440 / 230 V AC | 3-Phase | 4–5 kVA | 50 Hz

Product Overview

The Three-Phase Transformer Training System is a comprehensive educational training unit designed for practical study of three-phase transformer operation, characteristics, connections and electrical measurements.

The system enables students to perform no-load, short-circuit and load tests, study Star (Y) and Delta (Δ) winding configurations, measure electrical parameters and determine three-phase power using the two-wattmeter method.

The system incorporates a variable-voltage autotransformer arrangement for controlled variation of the primary voltage and provides clearly identified terminals and test points for safe and convenient practical experimentation.

Key Features

  • Three-phase transformer rated 4–5 kVA
  • Primary voltage: 440 V AC
  • Secondary voltage: 230 V AC
  • Frequency: 50 Hz
  • Variable primary voltage through autotransformer
  • Separate accessible transformer winding terminals
  • Star and Delta connection facilities
  • No-load, short-circuit and load-test capability
  • Voltage and current measurement facilities
  • Three-phase power measurement using two-wattmeter method
  • Suitable electrical protection and emergency-stop arrangement
  • Clearly marked terminals and test points
  • Robust industrial/educational construction
  • Supplied with teaching manual and practical exercises

Technical Specifications

Parameter

Specification

Equipment

Three-Phase Transformer Training System

Transformer Type

Three-phase educational transformer

Rated Capacity

4–5 kVA

Primary Voltage

440 V AC, 3-Phase

Secondary Voltage

230 V AC, 3-Phase

Frequency

50 Hz

Variable Voltage

Variable primary voltage using autotransformer

Primary Connection

Star / Delta

Secondary Connection

Star / Delta

Experiments

No-load, short-circuit and load tests

Measurements

Voltage, current, power and power factor

Power Measurement

Two-wattmeter method

Protection

Overcurrent, short-circuit and emergency protection

Terminals

Clearly identified safety/test terminals

Construction

Industrial-grade educational training system

Documentation

Teaching manual, experiment manual and connection diagrams

Educational Experiments

1. Study of Transformer at No Load

Students can determine and study:

  • Primary voltage
  • Secondary voltage
  • No-load current
  • Input power
  • Transformation ratio
  • No-load losses
  • Power factor

2. Short-Circuit Test

The system permits controlled short-circuit testing for studying:

  • Short-circuit voltage
  • Short-circuit current
  • Input power
  • Copper losses
  • Equivalent impedance
  • Transformer parameters

3. Load Test

The transformer can be connected to a suitable three-phase load to study:

  • Primary and secondary current
  • Input and output voltage
  • Load power
  • Power factor
  • Voltage regulation
  • Transformer losses
  • Efficiency

4. Star / Delta Connections

The accessible winding terminals allow students to construct and study applicable:

  • Star–Star (Y–Y)
  • Delta–Delta (Δ–Δ)
  • Star–Delta (Y–Δ)
  • Delta–Star (Δ–Y)

connections according to the transformer configuration and manufacturer's permitted connections.

5. Two-Wattmeter Method

The system provides suitable connection facilities for measurement of three-phase active power using two wattmeters.

Students can study:

  • Wattmeter readings
  • Total three-phase power
  • Power factor
  • Relationship between wattmeter readings and load conditions

Variable Voltage Arrangement

A variable-voltage autotransformer is provided for controlled variation of the transformer primary voltage.

The arrangement includes:

  • Smooth voltage adjustment
  • Voltage indication
  • Clearly marked input/output terminals
  • Appropriate protection
  • Safe connection facilities

The supplier shall state the exact adjustment range and rating of the offered autotransformer.

Measurement & Connection Panel

The front panel shall provide clearly identified sections for:

3-Phase Input → Variable Voltage → Measurement → Transformer Connections → Protection → Load/Test Points

The panel shall include suitable terminals for:

  • L1, L2, L3 and Neutral, where applicable
  • Primary transformer terminals
  • Secondary transformer terminals
  • Star connection
  • Delta connection
  • Voltage measurement
  • Current measurement
  • Wattmeter connections
  • Load connections
  • Protective earth

Protection & Safety

The training system shall incorporate appropriate safety provisions, including:

  • Input MCB/fuse protection
  • Output protection
  • Short-circuit protection
  • Overcurrent protection
  • Emergency-stop facility
  • Protective earthing
  • Insulated safety terminals
  • Clearly marked warning labels
  • Safe connection and measurement points

Recommended Accessories

The complete system shall include, as applicable:

  1. Three-phase transformer
  2. Variable-voltage autotransformer
  3. Digital voltmeters
  4. Digital ammeters
  5. Power measurement facility
  6. Two-wattmeter arrangement
  7. Three-phase load
  8. Protection devices
  9. Emergency-stop switch
  10. Safety connection leads
  11. Earthing arrangement
  12. Patch cords/test leads
  13. Connection diagrams
  14. Teaching manual
  15. Experiment/exercise manual

Teaching Manual

A comprehensive practical manual shall be supplied covering:

  • Transformer theory
  • Construction and working principle
  • Transformer ratio
  • Star and Delta connections
  • No-load test
  • Short-circuit test
  • Load test
  • Voltage regulation
  • Losses and efficiency
  • Power factor
  • Three-phase power
  • Two-wattmeter method
  • Observation tables
  • Calculation procedures
  • Result and conclusion formats
  • Safety procedures

Typical Front Panel Layout

3-PHASE INPUT
VARIABLE VOLTAGE / AUTOTRANSFORMER
PRIMARY & SECONDARY MEASUREMENT
STAR / DELTA TRANSFORMER CONNECTIONS
LOAD / TEST POINTS

Technical Details